Q01
When a project is opened in ETS6, which of the following is NOT one of the labelled elements of the project design view?- A.Status bar
- B.Tree view
- C.Sidebar
- D.Panel selector
7. ETS6 Professional· bars-views-search· EasyCorrect answerA — Status barLearning tipCorrect: The listed elements are Menu bar, Panel selector, Toolbars, Tree view, List view, Sidebar and Project tab. 'Status bar' is not among them.
Source: KNX Basic Course Documentation — 4.2.1 — p. 210Q02
The ETS6 Menu bar can be temporarily shown by pressing the CTRL key.TrueFalse7. ETS6 Professional· bars-views-search· EasyCorrect answerFalseLearning tipThe Menu bar is temporarily shown by pressing the ALT key, not CTRL.
Source: KNX Basic Course Documentation — 4.2.2 — p. 211Q03
When the Download button in the main toolbar is clicked, how does ETS decide what to download?- A.It always downloads the full application and address
- B.It selects the best download option for the device based on the device's flags
- C.It selects based on the device's bus current
- D.It asks the user to choose every time via a wizard
7. ETS6 Professional· bars-views-search· MediumCorrect answerB — It selects the best download option for the device based on the device's flagsLearning tipCorrect: When the Download button is clicked, ETS selects the best download option for this device based on the device's flags.
Source: KNX Basic Course Documentation — 4.2.4.1 — p. 215Q04
Which statement about the main toolbar's appearance is correct?- A.Buttons can be freely added and removed by the user
- B.The toolbar can be dragged to the bottom of the window
- C.Its colour scheme is user-configurable
- D.It is not possible to change the appearance of the main toolbar
7. ETS6 Professional· bars-views-search· EasyCorrect answerD — It is not possible to change the appearance of the main toolbarLearning tipCorrect: The source states it is not possible to change the appearance of the main toolbar.
Source: KNX Basic Course Documentation — 4.2.4.1 — p. 215Q05
What is the default selection of the connection manager opened from the main toolbar?- A.Automatic
- B.Manual
- C.USB
- D.IP Tunnelling
7. ETS6 Professional· bars-views-search· EasyCorrect answerA — AutomaticLearning tipCorrect: The connection manager opens with the default selection 'Automatic'.
Source: KNX Basic Course Documentation — 4.2.4.1 — p. 215Q06
Which numeric keys collapse and expand tree branches in the Tree view?- A.'+' expands and '-' collapses
- B.F2 expands and ENTER collapses
- C.'/' collapses and '*' expands
- D.'*' collapses and '/' expands
7. ETS6 Professional· bars-views-search· MediumCorrect answerC — '/' collapses and '*' expandsLearning tipCorrect: The numeric key '/' collapses a branch and '*' expands it.
Source: KNX Basic Course Documentation — 4.2.5.1 — p. 217Q07
How many search items will be saved?- A.Up to 15
- B.Up to 5
- C.Up to 10
- D.Up to 20
7. ETS6 Professional· bars-views-search· MediumCorrect answerA — Up to 15Learning tipCorrect: Up to 15 search items will be saved, sorted chronologically with the most recent on top.
Source: KNX Basic Course Documentation — 4.2.9 — p. 222Q08
Before you can download the individual address and/or application program from the commissioning PC to the KNX installation, the bus interface settings must have been set correctly.TrueFalse7. ETS6 Professional· commissioning· EasyCorrect answerTrueLearning tipThe source states that to configure the connection between a computer and a KNX installation (e.g. to download the individual address and/or application program), it is indispensable that the bus interface settings have been set correctly.
Source: KNX Basic Course Documentation — 7.3 — p. 278Q09
ETS distinguishes four download parts of a KNX device: the individual address, the application program(s), the group addresses (with their links/tables), and the parameters.TrueFalse7. ETS6 Professional· commissioning· EasyCorrect answerTrueLearning tipThe source lists exactly these download parts: Individual address, Application program(s), Group addresses (group addresses and the links between group objects, the tables), and Parameters.
Source: KNX Basic Course Documentation — 7.5.1 — p. 282Q10
Which download-status flag indicates that the application program(s) have been loaded into the device?- A.Adr
- B.Par
- C.Grp
- D.Prg
7. ETS6 Professional· commissioning· EasyCorrect answerD — PrgLearning tipCorrect: Prg indicates the application program(s) are loaded.
Source: KNX Basic Course Documentation — 7.5.1.1 — p. 282Q11
Which download flags are involved in the 'Download All' option?- A.Par and Grp only
- B.Adr, Prg, Par and Grp
- C.Adr only
- D.Prg only
7. ETS6 Professional· commissioning· MediumCorrect answerB — Adr, Prg, Par and GrpLearning tipCorrect: Download All transfers all project data and involves the Adr, Prg, Par and Grp flags.
Source: KNX Basic Course Documentation — 7.5.1.1 — p. 283Q12
What does the 'Download Partial' option transfer to the device(s)?- A.All project data, exactly like Download All
- B.Only the individual address
- C.Only the parts changed in ETS and not downloaded before (Parameters/Addresses and Application programs)
- D.Nothing until the device is restarted
7. ETS6 Professional· commissioning· MediumCorrect answerC — Only the parts changed in ETS and not downloaded before (Parameters/Addresses and Application programs)Learning tipCorrect: Download Partial sends only the changed, not-yet-downloaded parts, split into Parameters/Addresses and Application programs.
Source: KNX Basic Course Documentation — 7.5.1.1 — p. 283Q13
Under what condition can ETS assign an individual address without you physically pressing the device's download button?- A.When the device supports the KNX Serial Number feature and its serial number is entered in ETS
- B.Whenever the device is powered on the bus
- C.Only after the application program has been downloaded
- D.Never; the download button must always be pressed
7. ETS6 Professional· commissioning· MediumCorrect answerA — When the device supports the KNX Serial Number feature and its serial number is entered in ETSLearning tipSource: KNX Basic Course Documentation — 7.5.1.2 — p. 284Q14
For a device that does not support the KNX Serial Number feature, what does ETS ask you to do to download the individual address?- A.Enter the device's IP address manually
- B.Physically press the download button on the device, as prompted in the Pending Operations Sidebar
- C.Nothing; ETS assigns it automatically anyway
- D.Restart the device first
7. ETS6 Professional· commissioning· EasyCorrect answerB — Physically press the download button on the device, as prompted in the Pending Operations SidebarLearning tipCorrect: ETS asks, in the Pending Operations Sidebar, to physically press the download button.
Source: KNX Basic Course Documentation — 7.5.1.2 — p. 285Q15
Which Unload variant requires the device to be in Programming Mode?- A.Unload Application (only)
- B.Both variants require Programming Mode
- C.Unload Application and Address
- D.Neither variant requires Programming Mode
7. ETS6 Professional· commissioning· MediumCorrect answerC — Unload Application and AddressLearning tipCorrect: Unload Application and Address requires the device to be in Programming Mode.
Source: KNX Basic Course Documentation — 7.6 — p. 287Q16
The ETS diagnostics function requires direct bus access, so the computer must be connected to the KNX installation via a USB interface (KNX TP or RF USB) or an IP interface (KNX TP/IP).TrueFalse7. ETS6 Professional· diagnostics· EasyQ17
For a KNX RF S-Mode device whose programming mode is not switched off manually, what happens?- A.The device automatically switches off programming mode after 40 minutes
- B.Programming mode stays on until the next download
- C.The device automatically switches off programming mode after 4 minutes
- D.The device is damaged after 4 minutes in programming mode
7. ETS6 Professional· diagnostics· MediumCorrect answerC — The device automatically switches off programming mode after 4 minutesLearning tipCorrect: The source states RF S-Mode devices auto switch off programming mode after 4 minutes.
Source: KNX Basic Course Documentation — 8.2.2.1 — p. 296Q18
The three ETS telegram-monitoring tools are the Bus Monitor, the Group Monitor and the Project Check.TrueFalse7. ETS6 Professional· diagnostics· EasyCorrect answerFalseLearning tipFalse: the three monitors are the Bus Monitor, the ETS Bus Activity Monitor and the Group Monitor; the Project Check is an offline project test, not a monitor.
Source: KNX Basic Course Documentation — 8.2.3.1 — p. 300Q19
While the Bus Monitor is recording, which statement is true about other bus diagnostics?- A.All other diagnostics remain fully available
- B.You cannot check an individual address, do a line scan or search for programming-mode devices, because the Bus Monitor needs exclusive bus access
- C.Only downloads are blocked, everything else works
- D.Another Bus Monitor can run in parallel on the same interface
7. ETS6 Professional· diagnostics· MediumCorrect answerB — You cannot check an individual address, do a line scan or search for programming-mode devices, because the Bus Monitor needs exclusive bus accessLearning tipCorrect: The Bus Monitor requires exclusive bus access, so those functions are unavailable during its recording.
Source: KNX Basic Course Documentation — 8.2.3.1.1 — p. 300Q20
Which monitor lets you continue to check individual addresses, do a line scan or search for programming-mode devices while it is recording?- A.The Bus Monitor, because it records everything
- B.Neither monitor allows any other diagnostics during recording
- C.The Group Monitor, because it does not require exclusive bus access
- D.Both monitors always allow all other diagnostics
7. ETS6 Professional· diagnostics· MediumCorrect answerC — The Group Monitor, because it does not require exclusive bus accessLearning tipCorrect: The Group Monitor shares the bus, so those functions remain available during its session.
Source: KNX Basic Course Documentation — 8.2.3.1.3 — p. 301Q21
How many levels/checks does the Project Check perform, and which are they?- A.Three: Device, Group address and Topology checks only
- B.Four: Device, Group address, Topology and Bus Traffic checks
- C.Five: Device, Group address, Topology, Security and Licensing checks
- D.Five: Device check, Group address check, Topology check, Product Information check, and Checks for projects imported from earlier ETS versions
7. ETS6 Professional· diagnostics· MediumCorrect answerD — Five: Device check, Group address check, Topology check, Product Information check, and Checks for projects imported from earlier ETS versionsLearning tipCorrect: The source lists these five levels of the Project Check.
Source: KNX Basic Course Documentation — 8.2.4 — p. 318Q22
In the Topology Check, which default averages are used when the current properties are not available?- A.320 mA per device, 10 mA per power supply
- B.20 mA per device, 640 mA per power supply
- C.10 mA assumed per device, 320 mA assumed per power supply
- D.10 mA per device, 160 mA per power supply
7. ETS6 Professional· diagnostics· MediumCorrect answerC — 10 mA assumed per device, 320 mA assumed per power supplyLearning tipCorrect: The source specifies 10 mA per device and 320 mA per power supply as the assumed averages.
Source: KNX Basic Course Documentation — 8.2.4.3 — p. 320Q23
At what level does the Online Error Diagnostics wizard check for installation errors, and what does it require?- A.At the functionality level, i.e. group address level, and it requires an online connection to the bus
- B.At the topology level, and it works offline
- C.At the individual-address level only, with no bus needed
- D.At the licensing level, requiring a dongle
7. ETS6 Professional· diagnostics· MediumCorrect answerA — At the functionality level, i.e. group address level, and it requires an online connection to the busLearning tipCorrect: The source states it checks at group-address (functionality) level and needs an online bus connection.
Source: KNX Basic Course Documentation — 8.2.5 — p. 323Q24
What is the window that appears when ETS opens called?- A.The dashboard
- B.The panel selector
- C.The project workspace
- D.The catalog
7. ETS6 Professional· dashboard-and-projects· EasyCorrect answerA — The dashboardLearning tipCorrect: the window that appears when ETS opens is the dashboard.
Source: KNX Basic Course Documentation — 3.1.1 — p. 169Q25
How can you access the dashboard again at any time while ETS is running?- A.By restarting ETS each time
- B.By clicking the '+' button to open a new ETS (Overview) tab
- C.By pressing the SHIFT key
- D.It cannot be reopened during a session
7. ETS6 Professional· dashboard-and-projects· EasyCorrect answerB — By clicking the '+' button to open a new ETS (Overview) tabLearning tipCorrect: the '+' button opens a new Overview tab, giving access to the dashboard.
Source: KNX Basic Course Documentation — 3.1.1 — p. 169Q26
What can the dashboard's search bar do?- A.Search only projects in the local list
- B.Search only archived projects
- C.Quickly search for projects regardless of location - the local list or anywhere in the archive
- D.Search the online product catalog only
7. ETS6 Professional· dashboard-and-projects· MediumCorrect answerC — Quickly search for projects regardless of location - the local list or anywhere in the archiveLearning tipCorrect: the search bar spans the local list and the archive.
Source: KNX Basic Course Documentation — 3.1.1.2 — p. 169Q27
Which buttons does the dashboard's main toolbar contain?- A.Settings, Help and New Project
- B.New Project and Import Project
- C.Start Project Wizard and Export
- D.Settings and Help
7. ETS6 Professional· dashboard-and-projects· MediumCorrect answerD — Settings and HelpLearning tipCorrect: the main toolbar contains the Settings and Help buttons.
Source: KNX Basic Course Documentation — 3.1.1.3 — p. 169Q28
Where are locally stored ETS projects kept?- A.In the Project Archive only
- B.In the KNX Help Center
- C.In the 'Local Project Store', opened via the 'Local Projects' button
- D.In the online product catalog
7. ETS6 Professional· dashboard-and-projects· EasyCorrect answerC — In the 'Local Project Store', opened via the 'Local Projects' buttonLearning tipCorrect: locally stored projects are kept in the Local Project Store.
Source: KNX Basic Course Documentation — 3.1.2 — p. 171Q29
What is the purpose of project restore points?- A.To open an ETS project in one of its earlier stages
- B.To permanently delete old project versions
- C.To export a project to knxproj format
- D.To lock a project against editing
7. ETS6 Professional· dashboard-and-projects· MediumCorrect answerA — To open an ETS project in one of its earlier stagesLearning tipCorrect: restore points open a project in an earlier stage.
Source: KNX Basic Course Documentation — 3.1.5 — p. 177Q30
What does the abbreviation ETS stand for?- A.Engineering Tool Software
- B.Electrical Testing System
- C.European Telecom Standard
- D.Engineering Technical Setup
7. ETS6 Professional· ets-concept-requirements· EasyCorrect answerA — Engineering Tool SoftwareLearning tipCorrect: ETS stands for Engineering Tool Software, a registered trademark of the KNX Association.
Source: KNX Basic Course Documentation — 2.1.1 — p. 166Q31
What is the minimum CPU requirement for installing ETS6?- A.A processor of at least 1 GHz
- B.A processor of at least 3 GHz
- C.A processor of at least 2.5 GHz
- D.A processor of at least 2 GHz
7. ETS6 Professional· ets-concept-requirements· MediumCorrect answerD — A processor of at least 2 GHzLearning tipCorrect: the minimum CPU is at least 2 GHz.
Source: KNX Basic Course Documentation — 2.2.1.1 — p. 167Q32
What is the minimum RAM requirement for ETS6?- A.At least 4 GB
- B.At least 2 GB
- C.At least 8 GB
- D.At least 1 GB
7. ETS6 Professional· ets-concept-requirements· EasyCorrect answerA — At least 4 GBLearning tipCorrect: the minimum RAM is 4 GB.
Source: KNX Basic Course Documentation — 2.2.1.1 — p. 167Q33
What is the minimum storage (disk space) requirement for ETS6?- A.At least 10 GB
- B.At least 20 GB
- C.At least 40 GB
- D.At least 2 GB
7. ETS6 Professional· ets-concept-requirements· MediumCorrect answerB — At least 20 GBLearning tipCorrect: the minimum storage is 20 GB.
Source: KNX Basic Course Documentation — 2.2.1.1 — p. 167Q34
What is the minimum screen resolution required by ETS6?- A.800 x 600
- B.1280 x 1024
- C.1024 x 768
- D.1920 x 1080
7. ETS6 Professional· ets-concept-requirements· MediumCorrect answerC — 1024 x 768Learning tipCorrect: the minimum screen resolution is 1024 x 768.
Source: KNX Basic Course Documentation — 2.2.1.1 — p. 167Q35
Which operating systems are exclusively supported for an ETS6 installation?- A.Windows 10 (Version 20H2 or higher) and Windows 11
- B.Windows 10, Windows 11 and macOS
- C.Any Windows version plus Linux
- D.Windows 7 and Windows 8
7. ETS6 Professional· ets-concept-requirements· MediumCorrect answerA — Windows 10 (Version 20H2 or higher) and Windows 11Learning tipCorrect: these are the only supported operating systems.
Source: KNX Basic Course Documentation — 2.2.2.1 — p. 168Q36
In which file format does ETS6 export a project?- A..knxprod product file
- B..knxprojarchive
- C..vd5 file
- D..knxproj (the ETS6 project format)
7. ETS6 Professional· import-and-design· EasyCorrect answerD — .knxproj (the ETS6 project format)Learning tipCorrect: ETS6 exports projects only in the ETS6 project format, i.e. as a .knxproj file.
Source: KNX Basic Course Documentation — 5.4.3 — p. 249Q37
With an ETS Demo license, what is the maximum number of devices a project may contain in order to be exported?- A.5 devices
- B.20 devices
- C.10 devices
- D.Unlimited
7. ETS6 Professional· import-and-design· MediumCorrect answerA — 5 devicesLearning tipCorrect: a Demo license can export projects with a maximum of 5 devices.
Source: KNX Basic Course Documentation — 5.4.3 — p. 249Q38
How many devices can a project contain, at most, to be exported with an ETS Lite license?- A.5 devices
- B.20 devices
- C.50 devices
- D.Unlimited
7. ETS6 Professional· import-and-design· MediumCorrect answerB — 20 devicesLearning tipCorrect: a Lite license can export a project with a maximum of 20 devices.
Source: KNX Basic Course Documentation — 5.4.3 — p. 249Q39
What do files with the .knxprod extension contain?- A.An exported ETS project
- B.Manufacturer product data in the XML-Data format (from ETS4 onwards)
- C.A device plug-in package
- D.Bus monitor recordings
7. ETS6 Professional· import-and-design· EasyCorrect answerB — Manufacturer product data in the XML-Data format (from ETS4 onwards)Learning tipCorrect: .knxprod files are product data in the XML-Data format, used from ETS4 until today.
Source: KNX Basic Course Documentation — 5.6.1.1 — p. 252Q40
What is the default group address style of a new ETS project?- A.Two levels (main group / subgroup)
- B.Free style
- C.Four levels
- D.Three levels (main group / middle group / subgroup)
7. ETS6 Professional· import-and-design· EasyCorrect answerD — Three levels (main group / middle group / subgroup)Learning tipCorrect: a new project defaults to the three-level group address style.
Source: KNX Basic Course Documentation — 5.8.2 — p. 260Q41
What size is the Domain Address that ETS automatically generates for a new RF line?- A.3 bytes
- B.2 bytes (like a group address)
- C.16 bytes
- D.6 bytes
7. ETS6 Professional· import-and-design· MediumCorrect answerD — 6 bytesLearning tipSource: KNX Basic Course Documentation — 6.1.1 — p. 271Q42
Immediately after running the ETS6 setup on a fresh PC and starting ETS6, in what state does it run?- A.As demo, because the setup does not add a license
- B.As ETS6 Professional by default
- C.It refuses to start until a dongle is plugged in
- D.As ETS6 Lite, the free edition
7. ETS6 Professional· settings-and-licensing· MediumCorrect answerA — As demo, because the setup does not add a licenseLearning tipCorrect: There is only one ETS6 setup and it installs ETS6 as demo; the setup does not add a license.
Source: KNX Basic Course Documentation — 3.2.2 — p. 179Q43
After adding a license to the ETS6 software package, ETS6 becomes one of which editions?- A.ETS6 Professional, ETS6 Lite or ETS6 Demo
- B.ETS6 Professional, ETS6 Home or ETS6 Lite
- C.ETS6 Professional or ETS6 Bundle only
- D.ETS6 Standard, Home or Lite
7. ETS6 Professional· settings-and-licensing· MediumCorrect answerB — ETS6 Professional, ETS6 Home or ETS6 LiteLearning tipCorrect: Once a license is added, ETS6 becomes ETS6 Professional, ETS6 Home or ETS6 Lite.
Source: KNX Basic Course Documentation — 3.2.2 — p. 179Q44
Which statement correctly distinguishes the two ways to license ETS6 and its Apps?- A.Guided licensing never needs internet; manual licensing always needs internet
- B.Both methods require a permanent internet connection
- C.Neither method uses the internet at all
- D.Guided licensing needs internet only at the time of licensing; manual licensing needs no internet at the time of licensing
7. ETS6 Professional· settings-and-licensing· MediumCorrect answerD — Guided licensing needs internet only at the time of licensing; manual licensing needs no internet at the time of licensingLearning tipCorrect: Guided licensing requires an active internet connection only at the time of licensing, while manual licensing does not require internet at the time of licensing.
Source: KNX Basic Course Documentation — 3.2.2 — p. 179Q45
Which logging levels does ETS define, and which is the default?- A.Standard and Extended, with Standard as the default
- B.Standard and Extended, with Extended as the default
- C.Basic and Full, with Full as the default
- D.Minimal, Standard and Extended, with Standard as the default
7. ETS6 Professional· settings-and-licensing· MediumCorrect answerA — Standard and Extended, with Standard as the defaultLearning tipCorrect: Two logging levels are defined, Standard and Extended; by default the logging level is set to Standard.
Source: KNX Basic Course Documentation — 3.2.5.1 — p. 197Q46
For the Standard log level, how many events (n) before the trigger event are recorded to the log file?- A.1000
- B.500
- C.250
- D.5000
7. ETS6 Professional· settings-and-licensing· MediumCorrect answerB — 500Learning tipCorrect: For the Standard log level, n = 500 (trigger event type = ERROR).
Source: KNX Basic Course Documentation — 3.2.5.1 — p. 197Q47
In ETS6, where is the actual work within a project primarily carried out?- A.In the panels (Project Design views)
- B.In the Dashboard start screen
- C.In the Settings dialog
- D.In the online KNX Help Center
7. ETS6 Professional· panels· MediumCorrect answerA — In the panels (Project Design views)Learning tipCorrect: The source says the actual work within an ETS project is primarily done in panels.
Source: KNX Basic Course Documentation — 4.1.1 — p. 199Q48
What is the Buildings panel primarily used for?- A.Generating and defining group addresses
- B.Defining the bus structure and assigning individual addresses
- C.Creating the building structure and placing devices at their physical location
- D.Searching and inserting KNX products
7. ETS6 Professional· panels· MediumCorrect answerC — Creating the building structure and placing devices at their physical locationLearning tipCorrect: The Buildings panel creates building structures (Buildings, Functions, Trades) and lets you place devices into building elements.
Source: KNX Basic Course Documentation — 4.1.2 — p. 200Q49
What is the Group Address panel used for?- A.Creating the physical building structure
- B.Generating and defining group addresses
- C.Defining the bus structure and assigning individual addresses
- D.Producing project documentation and reports
7. ETS6 Professional· panels· MediumCorrect answerB — Generating and defining group addressesLearning tipCorrect: The source says the Group Address panel is used to generate and define group addresses.
Source: KNX Basic Course Documentation — 4.1.3 — p. 202Q50
What is the Topology panel used for?- A.To define the actual bus structure and assign individual addresses to devices
- B.To generate and define group addresses
- C.To create the physical building structure
- D.To produce the project's parts list
7. ETS6 Professional· panels· MediumCorrect answerA — To define the actual bus structure and assign individual addresses to devicesLearning tipCorrect: The source says the Topology panel defines the actual bus structure and the assignment of individual addresses.
Source: KNX Basic Course Documentation — 4.1.4 — p. 203Q51
How are devices shown in the Devices panel?- A.All devices in one list without any categorization
- B.Grouped by building and room
- C.Grouped by line and area
- D.Grouped by manufacturer
7. ETS6 Professional· panels· MediumCorrect answerA — All devices in one list without any categorizationLearning tipCorrect: The source says all devices are displayed in one list without any categorization.
Source: KNX Basic Course Documentation — 4.1.6 — p. 205Q52
When creating a new project, which group address style is selected by default?- A.Two Level
- B.Three Level
- C.Free
- D.Backbone
7. ETS6 Professional· project-creation-and-details· EasyCorrect answerB — Three LevelLearning tipCorrect: the Group Address Style setting defaults to Three Level in the New Project dialog.
Source: KNX Basic Course Documentation — 5.1.1.3 — p. 229Q53
A device has been locked with the project's BCU Key during download, and the key is now lost. Who can reset it?- A.The KNX Association, via a master key
- B.Any ETS6 Professional user with the project open
- C.Only the manufacturer
- D.The device resets itself automatically after 24 hours
7. ETS6 Professional· project-creation-and-details· MediumCorrect answerC — Only the manufacturerLearning tipCorrect: only the manufacturer is able to reset the BCU key of a password-protected device once the key is lost or forgotten.
Source: KNX Basic Course Documentation — 5.3.3.3 — p. 244Q54
Under what condition can a project password be disabled (cleared)?- A.At any time, by clicking 'Clear Password'
- B.Only after the project has been exported
- C.Only by the KNX Association
- D.Only if there are no devices in secure mode and no device certificates
7. ETS6 Professional· project-creation-and-details· MediumCorrect answerD — Only if there are no devices in secure mode and no device certificatesLearning tipCorrect: disabling a project password is only possible when there are no devices in secure mode or device certificates.
Source: KNX Basic Course Documentation — 5.3.3.2.3 — p. 243Q55
What does assigning a project password do?- A.Locks the project (no open/edit without it) and encrypts the exported project so its data cannot be read
- B.Only greys out the Details tab, with no effect on export
- C.Encrypts the export but still lets anyone open the project locally
- D.Prevents the project from ever being deleted
7. ETS6 Professional· project-creation-and-details· MediumCorrect answerA — Locks the project (no open/edit without it) and encrypts the exported project so its data cannot be readLearning tipCorrect: the password locks the project and encrypts it during export, so the exported data cannot be accessed (e.g. with a ZIP program).
Source: KNX Basic Course Documentation — 5.3.3.2.3.1 — p. 243Q56
What is the maximum length of a project password, and which characters are allowed?- A.Maximum 8 characters, letters and digits only
- B.Maximum 20 characters, any ASCII characters
- C.Maximum 16 characters, any ASCII characters
- D.Maximum 64 characters, any Unicode characters
7. ETS6 Professional· project-creation-and-details· MediumCorrect answerB — Maximum 20 characters, any ASCII charactersLearning tipCorrect: a project password can be at most 20 characters long and any ASCII characters can be used (and the entry is case-sensitive).
Source: KNX Basic Course Documentation — 5.3.3.2.3.1 — p. 243